Контакты
Product Features
● Ergonomic design
● Uniaxial or biaxial operation, spring reset
● Sturdy joystick for harsh environments
● Equipped with 2a@30VDC micro switch, independent switch output
● Upper handles for all types
Application
Drive proportional valves and switching valves for electro-hydraulic control
Rotary drilling RIGS, high-altitude fire engines, cranes, shield machines and other electrical and electro-hydraulic control systems.
Mechanical parameter | |
Angle | ±25° |
Operating force** | 10~20N(self return) |
Limit force | 300N |
Life | >2000,000(potentiometer) >5000,000(hall) |
Weight (base only) | 560g |
**93 mm from pivot point | |
Electric parameter | |
Analog/Hall voltage type | |
Voltage | 5.0 ± 0.5Vdc |
Current | <9mA |
Median voltage | 2.5±0.15V |
Output linear error | ±3% |
Maximum overload voltage | 30Vdc |
Max reverse voltage | -15Vdc |
Load resistance | >10KΩ |
Insulation resistance | >1000MΩ |
Analog/Hall voltage type | |
Current | 9~36Vdc |
Resistance | 5KΩ,10 KΩ |
Median dead zone Angle | ±3° |
Max power | 0.2W |
Micro switch | |
Configuration | 2 micro switches per axis, normally on |
Opening Angle | 2˚~5˚ |
Load capacity | 10A@30Vdc(Resistive load) |
Insulation Resistance | Above 100MΩ(500Vdc load capacity) |
Enviromental parameter | |
Operating temperature | -30℃~+80℃ |
Storage temperature | -40℃~+85℃ |
Protection grade | IP65 (above plate) |
Product Selection | |
Model | D191 - ① - ② - ③ - ④- ⑤ |
① operating mode | |
SA | Spring return, single-axis forward and backward directional operated |
DAC | Spring return, dual-axis cross directional operated |
DAP | Spring return, dual-axis arbitrary directional operated |
② Output | |
H51 | Hall effect, each axis of single hall sensor,5Vdc power supply,0.5~2.5~4.5V output voltage |
H52 | Hall effect, each axis of single hall sensor,5Vdc power supply,0~2.5~5.0V output voltage |
P051 | Potentiometer,<36Vdc power supply, with 5KΩ center-tapped potentiometer,0%-100%Vdc output |
P101 | Potentiometer,<36Vdc power supply, with 10KΩ center-tapped potentiometer,0%-100%Vdc output |
NA | No analog output |
③ Micro switch | |
N | No micro switch |
S1 | Single axis with a normally open switch in the middle position |
S2 | Single axis with two normally open switches in front and rear directions |
S4 | Dual axis, each axis with two normally open switches in front and back direction |
④ Handle | |
M | M handle, top palm operated |
C | C handle,top without button |
CS | C handle,top with button |
W | W handle,with deadman switch and trigger switch |
WS | W handle,with deadman switch and top self locking button |
⑤ Wires connection | |
L | Direct cable outlet (cable specification: AF200,28#, outlet length: 500mm) |
C | Terminal outlet |